Abstract

In bone and joint infections, several materials can be used for local antibiotic elution at site of infection. Polymethylmethacrylate (PMMA) cement is often used. Recently the use of antibiotic impregnated dissolvable synthetic pure calcium sulphate beads [Stimulan R]1 has been used as an alternative, due to several perceived advantages.

We present our experience of using Calcium sulphate beads in infections involving the upper limb.

From Jan 2012 to Jan 2015, we used Calcium sulphate beads in 7 complex upper limb infections including 1 elbow replacement, 2 infected non unions, 2 shoulder replacement, 1 wrist fusion and I ORIF elbow.

We used combination of Vancomycin and Gentamicin in the beads, using manufacturer's mixing guide for optimum setting.

Arthroplasty infections underwent explantation, addition of antibiotic impregnated calcium sulphate beads in the joint space, followed by a second stage, and systemic antibiotics. Fracture non-union cases had surgical debridement, calcium sulphate beads and systemic antibiotics

Follow up (6months to 2 years) indicate no recurrence of infection in any case.

The most common organisms isolated were Coagulase negative staphylococcus and Staphylococcus aureus. Others included Group B Streptococcus, Serratia marscesens and Corynebacterium spp.

In 2 of 7 cases there was significant drainage from the wound. This settled without further input.

For fracture non-union fixation, there was no need to do second procedure to remove beads as they dissolve. In cases of staged revisions, the beads were inserted at first stage with microbiological clearance at 2nd stage

At present there are no reports in the literature of the use of this product in the upper limb. Our experience suggests use of dissolvable pure Calcium sulphate beads impregnated with selected antibiotics, is an effective adjunct to current treatments.

Aseptic drainage has been reported and this was seen in some of our cases. It is postulated that the use of Calcium sulphate beads in more superficial joints may lead to more drainage. It may be necessary to avoid packing any beads in the subcutaneous spaces and using lower volumes in upper limb.

Further work will include long-term follow up and any evidence of relapse or recurrence of infection.