General Orthopaedics

THE EFFICACY OF INJECTABLE BIPHASIC CALCIUM SULPHATE/HYDROXYAPATITE BONE SUBSTITUTE CERAMENT™ G IN THE TREATMENT OF SEVERE BONE INFECTIONS

European Bone And Joint Infection Society (EBJIS) 34th Annual Meeting: PART 1



Abstract

Autologous bone grafting for bone defect reconstruction is associated with complications including donor site morbidity, infection risk, pain and surgical time. Therefore, bone graft substitutes provide an alternative for distinct indications and different characteristics with regard to their mechanical properties and resorption rates. In order to fill the loss of bone substance and to control the infection, we tried the efficacy of Cerament™G, a new absorbable composite of Calcium Sulphate and Hydroxyapatite with Gentamicin.

We present 3 male patients aged between 45 and 68 years affected by post-traumatic severe septic non union of femur, tibia and foot. The first patient with femur fracture was involved in a car accident (mixed flora Acinetobacter Baumanii, MRSA and Klebsiella pneumoniae carbapenemase (KPC)-producing), the second patient with femur and foot fracture falled by height in a work accident (MRSA) and the third one had a chronic tibial osteomyelitis several years after a road accident (Pseudomonas Aeruginosa). All 3 patients had undergone previous surgery. The first patient had several operations including multiple bone resection and debridement with external fixator, occlusion of superficial femoral artery with arterial bypass and finally debridement with implantation of Cerament™ G with external fixator and long term antibiotic therapy. The other 2 patients were subjected to resection of tissue septic with debridement, implantation of Cerament™ G and soft tissue closure and systemic antibiotics. Clinical and radiographic outcome were assessed at final follow-up (mean 8 months; range 8–18)

The follow-up was 8–18 months with examining clinical, radiographic, CT scan and laboratory tests. The patients had self-limiting fluid leakage. There was no recurrence of infection during the follow-up period. Bone ingrowth occurred in all cases with limb shortening.

Cerament™ G gives good elution of antibiotic and allows bone ingrowth. The implantation of Cerament™ G was associated with good clinical outcomes and satisfactory bone consolidation.

We acknowledge Antonella Esposito for septic nursing assistance