header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

INTRA-OPERATIVE COMPLICATIONS: A TRIP THROUGH NEVERLAND

Current Concepts in Joint Replacement (CCJR) – Spring 2015



Abstract

Intra-operative complications vary from extremely benign such as glenoid vault penetration to life and limb threatening for example brachial artery injury. Most intra-operative complications can be avoided with careful pre-operative planning, anticipation, and execution. However, even the best planning and execution including fluoroscopic guided reaming cannot prevent all complications. The following intra-operative complications will be discussed in detail in regards to both prevention and management: Glenoid vault penetration, Glenoid component malposition - reverse and primary, Glenoid fracture - reverse and primary, Humeral component malposition - reverse and primary, and Humeral fracture - reverse and primary.