General Orthopaedics

THE NON-CEMENTED HUMERUS: THE OPTIMAL HYBRID SOLUTION – OPPOSES

Current Concepts in Joint Replacement (CCJR) – Spring 2015



Abstract

Hybrid fixation of total joint arthroplasty has been an accepted form of surgical approach in multiple joints. Principles of implant fixation should focus on durability providing secure long-term function. To date there is no conclusive evidence that pressed fit humeral stem fixation has an advantage over well-secured cemented humeral fixation. In fact, need for revision arthroplasty due to inadequate implant fixation has almost universally revolved around failure of cement fixation and loosening of the glenoid component. A case will be made based on 30 years of experience of one surgeon performing total shoulder arthroplasty using secure modern cement fixation techniques of humeral components. More recently, over the last 10 years, extremely high rate of durable secure glenoid implant fixation has been achieved using tantalum porous anchorage with polyethylene glenoid components. This has resulted in no cases of loosening of glenoid fixation and only 1 case of glenoid component fracture with greater than 95% survivorship over a 10 year period. A combination of well cemented humeral stem and trabecular metal anchorage of the glenoid has provided durable lasting function in primary total shoulder arthroplasty.