Abstract

Introduction

Anatomical reconstruction of the Anterior Cruciate Ligament (ACL) reconstruction has been shown to improve patient outcome. The posterior border of the anterior horn of the lateral meniscus (AHLM) is an easily identifiable landmark on MRI and arthroscopy, which could help plan tibial tunnel position in the sagittal plane and provide anatomical graft position intra-operatively.

Method

Our method for anatomical tibial tunnel placement is to establish the relation of the posterior border of AHLM to the centre of the ACL footprint on a pre-operative sagittal MRI. Based on this relationship studied on preoperative MRI scan, posterior border of AHLM is used as an intra- operative arthroscopic landmark for anatomic tibial tunnel placement during ACL reconstruction. This relationship has been studied on 100 MRI scans where there was no ACL or LM injury (Bone and Joint Journal 2013 vol 95-B, SUPP 19). The aim of the study is to validate our method for anatomical tibial tunnel placement.

Results

25 patients with ACLR where there were both pre and post op MRI scan with good quality images of AHLM and tibial tunnel opening were included in this study. The preoperative relationship between posterior border of AHLM and centre of ACL footprint was compared with that between the posterior border of AHLM and centre of tibial tunnel on postop MRI scans. The measurements were done by two observers on two different occasions to establish intra and inter observer correlation.

Discussion and Conclusion

There was significant correlation between pre-op (0.4mm) and post-op (0.4mm) distances between the AHLM and the centre of the ACL footprint/graft. There was significant inter-observer correlation (paired T-test =0.89, p<0.05) in pre- and post-op measurements. No significant difference was found in the difference between the means in pre-op and post-op MRI scans between observers (p=0.79). These results suggest that the AHLM is a reliable and valid intra-operative marker for anatomic ACL tibial tunnel placement.