header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

THE JUMBO CUP: CURTAIN CALLS AND CAVEATS

Current Concepts in Joint Replacement (CCJR) – Winter 2014



Abstract

Using the Mayo Clinic definition (>62mm in women and >66mm in men), the “jumbo acetabular component” is the most commonly used method for acetabular revisions now. There are numerous advantages: surface contact is maximised; weight-bearing is distributed over a large area of the pelvis; the need for bone grafting is reduced; and usually, hip center of rotation is restored. The possible disadvantages, or caveats, of jumbo cups include: may not restore bone stock; may ream away posterior column or wall; screw fixation required; the possibility of limited bone ingrowth and late failure; and a high rate of dislocation due to acetabular size:femoral head ratio.

The techniques for a successful jumbo revision acetabular component involve: sizing-“reaming” of the acetabulum, careful impaction to achieve a “press-fit”, and multiple screw fixation. We recommend placement of an ischial screw in addition to dome and posterior column screw fixation. Cancellous allograft is used for any cavitary defects. The contraindications for a jumbo acetabular cup are: pelvic dissociation; inability to get a rim fit; inability to get screw fixation; and the presence of <50% living host bone. If stability cannot be achieved with the jumbo cup alone, then use of augment(s), bulk allograft, or cup-cage construct should be considered.

Our results with the jumbo acetabular cups in revision arthroplasty have been reported. Using predominantly titanium fiber-metal mesh components, we reported the 15-year survival of 129 revisions. There was 3% revision for deep infection and only 3% revision for aseptic loosening. There were 13 reoperations for other reasons: wear, lysis, dislocation, femoral loosening, and femoral fracture fixation. The survival was 97.3% at 10 years, but it dropped to 82.8% at 15 years. Late loosening of this fiber metal mesh component is likely related to polyethylene wear and loss of fixation. Dislocation is the most common complication of jumbo acetabular revisions, approximately 10%, and these are multifactorial in etiology and often require revision. Based on our experience, we now recommend use of an acetabular component with an enhanced porous coating (tantalum), highly cross-linked polyethylene, and large femoral heads for all jumbo revisions.