header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

SEVERE BONE LOSS AND PELVIC DISCONTINUITY: THE CUP CAGE SOLUTION

Current Concepts in Joint Replacement (CCJR) – Winter 2013



Abstract

Pelvic discontinuity with associated bone loss is a complex challenge acetabular revision surgery. Reconstruction by the use of ilio-ischial cages combined with trabecular metal acetabular components and morsellised bone (the component-cage technique) is a relatively new method of treatment. The trabecular cup provides a good environment for bone graft remodeling and eventual bone or fibrous ingrowth. The cage protects the trabecular metal cup until stabilisation occurs. The cage not only protects the cup but places the articulating center at the correct level.

We reviewed a consecutive series of 32 cases of acetabular revision reconstructions with pelvic discontinuity who had been treated by the cup-cage technique. The mean follow-up was 38 months (24.0 to 68.0). Failure was defined as a migration of a component of >5mm.

In 29 hips there was no clinical or radiological evidence of loosening at the last follow-up. The Harris hip scores improved significantly from 44.6 (sd 10.4) to 78.7 (sd 10.4) points (p<0.001).

In three hips (11.5%) the construct migrated at one year after surgery. The complications included two cases of dislocations, one of infection and one of partial palsy of the peroneal nerve. Our findings indicated that the treatment of pelvic discontinuity by the component-cage construct is a reliable option.