header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Femoral Bone Mineral Density Loss After Short Stem Neck-Sparing, Resurfacing, and Conventional Hip Arthroplasty

International Society for Technology in Arthroplasty (ISTA)



Abstract

Introduction:

Significant proximal femoral remodeling occurs after total hip arthroplasty (THA), with regions of bone loss, and regions of hypertrophy. This study compared three implants for changes in femoral bone mineral density over 2 years following primary uncemented hip arthroplasty with a conventional stem (THA), a novel femoral neck-sparing short hip stem (NS-THA), and resurfacing hip arthroplasty (RHA).

Methods:

Seventy-one patients participated in this non-randomized, prospective study. All patients had a diagnosis of osteoarthritis and underwent primary uncemented hip arthroplasty. Dual Energy XRay Absorptomitry (DXA) scans were performed at preoperative, 3–7 days post-op, 6 weeks, 6 months, one, and two years post-op. Using custom 2 cm zones, 19 zones were observed for percent changes in bone mineral density (BMD). Radiographs and Harris Hip scores were obtained at each visit.

Results:

Age, gender, and BMI were found to be statistically different with fewer females and lower age in the RHA group, and a lower age in the NS-THA group. In all three groups, regions that were located proximally were shown to be the most susceptible to bone loss. Combined 2 cm zones 1C/7C, 2A/6A, and 2B/6B showed statistical significance (p < 0.05). Bone loss in the proximal regions was 8–10% lower with the femoral neck-sparing short stem, and least in the RHA group, causing little to no BMD loss in proximal regions. Radiographic outcomes and clinical results including Harris Hip scores were equal between the groups.

Conclusion:

Consistent with our hypothesis, it was found that hip arthroplasty with a conventional stem resulted in the highest proximal femoral bone loss, and resurfacing arthroplasty was associated with the least bone loss. The femoral neck-sparing short stem ameliorated the bone loss seen with traditional hip arthroplasty, and approximated the bone preservation seen with hip resurfacing. The short stem neck-sparing device may provide some of the benefits of hip resurfacing, but could potentially have wider indications for use.


*Email: