header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

High Reliability in Total Knee Replacement Surgery: Is It Possible?

International Society for Technology in Arthroplasty (ISTA)



Abstract

The development of the High Reliability Organization focused on safety in organizations such as nuclear power plants, to avoid catastrophes in an environment where accidents might be expected due to risk factors and complexity. (Figure 1) The Agency for Healthcare Research and Quality applied High Reliability Concepts to hospitals in an effort to improve safety and quality.

The Institute for Healthcare Improvement has further expanded this approach to include establishing processes to ensure highly reliable care through analysis, design or redesign, using a model for improvement, and supported by technology and the physical environment.

These concepts can be applied to total knee replacement by identifying key processes, conducting regular measurement and analysis, and ensuring daily problem solving to create and maintain process reliability.

The application of patient specific technology to our conventional total knee replacement procedures creates an opportunity to improve both quality and safety in total knee replacement procedures. Preoperative imaging and use of computer software allows the surgeon to develop an individual blueprint for each operative procedure. A patient specific cutting guide is fabricated for use in surgery. Intra-operative measurement of bone cuts with comparison to the planned blueprint allows correction of inaccurate bone cuts during surgery. Post operative CT scanning provides a final accurate check of limb, knee and implant alignment in 3 dimensions, with comparison to the preoperative plan. Feedback from the surgeon to the engineers involved in the planning process allows daily improvement of the guide fit, cut accuracy and accuracy of limb, knee and implant alignment for these procedures.

Patient reported outcome measures such as the Oxford Knee Score or WOMAC score can be carried out preoperatively and at 6 months post op, to assess reduction of pain and functional improvements resulting from the operative procedure.

Ongoing annual patient surveillance using the 12 questions on the Oxford Knee Score, one question about satisfaction, and one question asking if the patient has undergone further surgery on the operative knee, can help assess the durability of the patient outcomes and the longevity of the prosthesis.

Use of patient specific cutting guides, coupled with preoperative software for planning a kinematically aligned TKA, has demonstrated improved RCT outcomes at the Phoenix VA. Figure 2 compares the distribution of WOMAC scores for kinematically aligned and mechanically aligned TKA. Individualizing the alignment for each patient has narrowed the distribution of the scores, with 87% of the kinematically aligned scores better than the median score for mechanically aligned patients.

There have been additional recent preoperative, perioperative and postoperative processes and checklists designed to increase quality and safety of TKA. Medical team training for preoperative briefing and post operative debriefing, use of the AAOS new STEPPS training program, monitoring post operative results with the NSQIP/VASQIP program and database give us additional tools to improve safety and quality. Coupled with patient specific alignment technology, I believe we currently have an excellent opportunity to move toward High Reliability in total knee replacement.


*Email: