What Is the Best Surgical Exposure in 2-Stage Revision Knee Replacement for Septic Loosening? Tibial Tubercle Osteotomy vs Quad Snip - Randomized Comparative Evaluation of 87 Patients at a Mean Follow

International Society for Technology in Arthroplasty (ISTA) 2012 Annual Congress



Abstract

INTRODUCTION

Conventional surgical exposures are usually inadequate for 2-stage revision knee replacement ofinfected implants. Reduced range of motion, extensor mechanism stiffness, peripatellar contracture and soft tissue scarring make patellar eversion difficult and forced eversion places the integrity of the extensor mechanism at risk. On the contrary, a wide exposure is fundamental to allow complete cement spacer removal, soft tissue balancing, management of bone loss and reimplantation without damaging periarticular soft tissues.

OBJECTIVES

To compare the long-term clinical, functional and radiographic results and the reinfection rate of the quadriceps snip approach and the tibial tubercle osteotomy in 2-stage revision knee replacement performed for septic loosening of the primary implant.

METHODS

In our department, 87 patients had a 2 stage revision knee replacement for septic loosening of the primary implant between 1996 and 2008. In all patients, first stage consisted of primary implant removal, extensive soft tissue debridement and positioning of a static antibiotic loaded cement spacer. The timing for reimplantation was decided basing on negative clinical and laboratory (ESR, CRP) signs and negative Leukoscan results. For reimplantation, a quadriceps snip was used in patients with an intraoperative flexion >90° (Group A) while a tibial tubercle osteotomy (Group B) was used in patients with an intraoperative flexion <90°.

RESULTS

At observation point, 4 patients died for reasons unrelated to surgery, leaving 42 patients in Group A and 41 in Group B. We had a total amount of 10 recurrent infections (11%) after reimplantation, 7 patients in Group A and 3 patients in Group B (p<0.005). Patients with a reinfection in Group A were treated with a knee fusion in 4 cases, a rerevision in 2 cases and an amputation above the knee in 1 case, while all those with a reinfection in Group B had a knee fusion. According to HSS score, 11 patients were rated as Excelent/Good in Group A and 9 patients in Group B (p=n.s.).

Three patients had a major complication in Group A and 0 patients in Group B (p=0.005). No differences were found between the two groups regarding range of motion and subjective satisfaction.

CONCLUSION

Tibial tubercle osteotomy is a safe procedure to obtain a wide exposure in 2-stage revision knee replacement performed for septic loosening of the primary implant and it is effective in reducing reinfection rate without compromising clinical results and range of motion.