header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Effect on lung functions in patients with thoracic adolescent idiopathic scoliosis treated by posterior spinal fusion with or without thoracoplasty

British Orthopaedic Association 2012 Annual Congress



Abstract

Introduction

There are controversies in the literature about thoracoplasty and its effect on lung function changes. The aim of the study was to evaluate the effect and outcome of thoracoplasty in conjunction with pedicle screw construct in the treatment of thoracic adolescent idiopathic scoliosis on lung functions.

Materials and methods

It is a retrospective study of consecutive series of 62 patients with thoracic adolescent idiopathic scoliosis surgically treated by single surgeon between 2007 and 2008 at a tertiary referral Orthopaedic Spinal unit. Posterior spinal fusion and thoracoplasty (n=32, all but one girls) were compared with 30 without thoracoplasty (all but one girls). Clinical and radiographic analysis was performed, including the SRS-30 questionnaire and Pulmonary Function Tests (PFT). Absolute and percent-predicted values of forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and total lung capacity (TLC) were evaluated preoperatively and at 3-months, 1 year and/or 2-year follow-up, and comparisons were made between two groups. The minimum follow-up was one year.

Results

No statistical differences were found between the two groups in PFT's both pre-operatively and at latest follow up ranging 1 to 3 years. Our findings suggest that thoracoplasty did not adversely affected long-term PFT's in AIS patients compared to patients treated by posterior spinal fusion alone. Three-month postoperative pulmonary function test values in both groups experienced 15–30% decline which returned to the preoperative baseline at 1 year in > 90% patients. In thoracoplasty group, 5 to 8 ribs were resected and used for bone graft. Chest complications were observed in 2 patients requiring chest drainage. Prolonged donor site morbidity was noted in 3 patients.

Conclusions

Thoracoplasty showed comparable clinical and radiological correction without any significant pulmonary function compromise. Pulmonary function test values returned to the preoperative baseline at 1 year in > 90% patients.