SAFETY OF PERCUTANEOUS ANTERIOR COLUMN SCREW STABILIZATION IN ACETABULAR FRACTURES

Canadian Orthopaedic Association (COA)



Abstract

Purpose

Anterior column screw fixation has been a useful tool in the management of acetabular fractures, either alone or in combination with other fixation techniques. Percutaneous insertion may be advantageous by limiting surgical dissection but little has been reported on its safety. The purpose of this study is to report on the efficacy and safety of percutaneous anterior column stabilization.

Method

In a consecutive series of 122 operatively treated acetabular fractures, 56 patients were treated with antegrade percutaneous anterior column stabilization either alone or in combination with other fixation techniques by a single surgeon (JY). The technique was selected when the anterior column portion of the fracture was undisplaced or could be reduced via indirect methods. Intraoperative fluoroscopy was used to guide the placement of either a 6.5 mm or 7.3 mm cannulated antegrade anterior column lag screw. Postoperative radiographs (anteroposterior and Judet views) were obtained in the recovery room, prior to discharge and at clinic follow up.

Results

The mean age of patients in the series was 52 years (range 17 91). Mean follow up was 13 months. There was one death from associated injuries. Based on the classification system described by Letournel, there were 22 anterior column, 8 transverse, 11 transverse / posterior wall, 9 anterior column / posterior hemitransverse, 1 associated both column and 5 T-type fractures. There were no vascular, neurologic, or urologic complications in the series. There were no cases of intraarticular screw placement. In two cases, the screw did not completely cross the entire fracture line on postoperative radiographs. There were no cases of hardware failure or loss of reduction. There were two cases of hardware removal for hardware prominence. There was one case of chronic proximal femur osteomyelitis, and two cases requiring subsequent total hip arthroplasty for associated injuries. All fractures healed.

Conclusion

This study supports percutaneous anterior column stabilization as a safe and effective technique in the treatment of selected acetabular fractures.