header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

RANDOMISED CONTROLLED STUDY ANALYSIS OF FIXED BEARING AND ROTATING PLATFORM TOTAL KNEE ARTHROPLASTY – MINIMUM 2 YEAR REVIEW

Canadian Orthopaedic Association (COA)



Abstract

Purpose

Prospective randomized intervention trial to determine whether patients undergoing rotating platform total knee arthroplasty have better clinical outcomes at two years when compared to patients receiving fixed bearing total knee arthroplasty as measured by the WOMAC, SF-36 and Knee Society (KSS) scores.

Method

67 consecutive patients (33 males and 34 females; average age 66 years) were randomized into either receiving a DePuy Sigma rotating platform (RP) total knee arthroplasty (29 patients) or a DePuy Sigma fixed bearing (FB) total knee arthroplasty (38 patients). Inclusion criteria included patients between the ages of 45–75 undergoing single-sided total knee arthoplasty for clinically significant osteoarthritic degeneration.

Pain, disability and well-being were assessed using the WOMAC, KSS, and SF-36 preoperatively and at 6 months, 1 year and 2 years post-operatively. In addition, intraoperative measures were collected. Pre-operative radiographs were analyzed using the Kellgren and Lawrence Score, modified Scotts Scoring and mechanical axis. Post-operative radiographs were collected at 1 and 2 years and analyzed to identify evidence of prosthetic loosening, implant positioning and limb alignment.

Results

The two groups were well-matched following randomization (age, BMI, side) and had no significant differences in intraoperative measures (operative time, estimated blood loss). There were no differences in the groups with respect to their preoperative radiographs. The average female patient was younger compared to their male cohorts (mean female = 63; mean male 68 p=0.005).

The post-operative radiographs did not reveal any differences between RP and FB groups when comparing sagittal alignment of femoral and tibial components, patellar tilt and patellar location.

With respect to clinical outcomes, both groups reported statistically significant improvements in KSS, WOMAC and SF-36 scores. There were no differences in their pre- and post-operative SF-36 mental component scores. The 1 year WOMAC function score was significantly higher (worse outcome) in the FB group (mean = 18) compared to the RP group (mean 7.8) (p < 0.01). Two year KSS scores were significantly higher (better outcome) in the FB group (mean = 95.7) compared to the RP group (mean = 85.9) (p < 0.05).

Conclusion

Both rotating platform and fixed bearing total knee arthroplasty result in clinical improvement over pre-operative function, but has no effect on the mental component of the SF-36. The current study suggests that there is not a clear benefit in selecting either a rotating platform or a fixed bearing total knee system; rather both implants result in improved function. Interestingly, when comparing the results of the WOMAC and KSS, although both measure functional outcomes, when applied to the same population demonstrate differing sensitivity.