Trauma

ELECTROPHYSIOLOGIC EVALUATION OF THE SUPRASPINATUS MUSCLE. A NEW EXPERIMENTAL MODEL ON RATS

European Federation of National Associations of Orthopaedics and Traumatology (EFORT) - 12th Congress



Abstract

Purpose of this study is to create an experimental model of electrophysologic evaluation of the supraspinatus muscle on rats, after traumatic rupture of its tendon.

The population of this study consisted of 10 male Sprague Dawley rats weighting 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The scapula was immobilized, and the supraspinatus tendon was attached to a force transducer using a 3–0 silk thread. A dissection was performed in order to identify the suprascapular nerve, which was then stimulated with a silver electrode. Stimulations were produced by a stimulator (Digitimer Stimulator DS9A) and were controlled by a programmer (Digitimer D4030). Fiber length was adjusted until a single stimulus pulse elicited maximum force during a twitch under isometric conditions. Rectangular pulses of 0.5 ms duration were applied to elicit twitch contractions. During the recordings, muscles were rinsed with Krebs solution of approximately 37 8C (pH 7.2–7.4) and aerated with a mixture of 95% O2 and 5% CO2. The output from the transducer was amplified and recorded on a digital interface (CED).

The following parameters were measured at room temperature (20–21 8C): single twitch tension; time to peak; half relaxation time; tetanic tensions at 10, 20, 40, 80 and 100 Hz; and fatigue index, which was evaluated using a protocol of low frequency (40 Hz) tetanic contraction, during 250 ms in a cycle of 1 s, for a total time of 180 s. The fatigue index value was then calculated by the formula [fatigue index=(initial tetanic tension − end tetanic tension) ∗ 100/(initial tetanic tension)]. In the end, the transducer was calibrated with standard weights and tensions were converted to grams.

The mean single twitch was 8.2, the time to peak 0.034 msec and the half relaxation time 0.028 msec. The strength of titanic muscle contractures was 5.7 msec at 10Hz and 17.7 at 100Hz. Finally, the fatigue index was calculated at 48.4.

We believe that electrophysiologic evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair