THE USE OF AUTOTRANSFUSION IN TOTAL KNEE REPLACEMENT. LONG TERM RESULTS IN A PROSPECTIVE STUDY

European Federation of National Associations of Orthopaedics and Traumatology (EFORT) - 12th Congress



Abstract

Purpose

To evaluate the long term results of the use of a postoperative autologous blood reinfusion system in total knee arthroplasty.

Material and method

In a prospective study, 176 patients who underwent unilateral total knee replacement, during the period 2004–2008, were evaluated (study group or group A). In all these patients a reinfusion system of unwashed blood salvaged was applied, while supplementary homologous blood transfusion was performed when required. The admission of banked blood transfusion determined by haemoglobin value (<9mg/dL) and/or clinical signs (blood pressure, pulses, etc). The value of haemoglobin, haematocrite and platelets recorded preoperatively and the 1st, 5th and 15th day after operation. Results were compared with the material of our previous prospective randomized controlled study (control groups B and C), where in 60 patients, between the years 2002–2004, the effectiveness of postoperative autologous blood reinfusion had been proved.

Results

19 patients of group A required postoperatively 23 units of homologous blood (total study group requirements23 blood units or 0.13 units per patient) while in group B required 1.5 units/patient and in group C 0.3 units/patient. In the study group the total homologous blood requirements reduced by 91% compared with group B (patients without autotransfusion system applied) and by 47% compared with group C (patients with autotransfusion system applied). There was no statistically significant difference in the postoperative values of Hb and Ht between the groups. None of the patients developed any adverse reactions after reinfusion. The cost of blood management was reduced in study group by 76%.

Conclusions

The use of an autotransfusion system postoperatively minimizes practically the demands for homologous banked blood transfusion in total knee arthroplasty.