BIOMECHANICAL COMPARATIVE STUDY BETWEEN OF TWO TECHNIQUES FOR STABILIZATION OF SUICIDAL JUMPER'S FRACTURE

European Federation of National Associations of Orthopaedics and Traumatology (EFORT) - 12th Congress



Abstract

Background

The suicidal jumper's fracture of the pelvis is a special form of sacrum fractures associated with high energy trauma. The typical H-type fracture pattern runs transforaminal on both sides with a connecting transverse component between S1 and S3. Due to the high-grade instability operative treatment is imperative. Aim of this study was to compare iliosacral double screwing (2×7,3mm canulated screw with 16mm thread) with spinopelvic internal fixation.

Methods

Both methods were tested on 6 synthetic and 6 anatomical pelvises. After osteotomy and alternating osteosynthesis stability was tested with a universal testing machine (Zwick) in a simulated two-leg stand. Data were generated by a 3-dimensional computer-assisted ultrasoundsystem (Zebris©) (3 translational datasets x,y,z and 3 ankles). Testing was performed after preload of 50N and two setting cycles of 100N followed by a full load cycle of 150N. ASCII-data were then transferred to SPSS for statistical analysis.

Results

Both experimental series showed similar results. There was a tendancy of less displacement when iliosacral screwing was performed. However, no statistical significance could be observed between both techniques.

Discussion

Although the spinopelvic internal fixation is a more rigid system, the double screwing may compensate this as it interacts in the center of the fracture. We therefore think that iliosacral double screwing is an appropriate technique for stabilisation of this special fracture type. The possibility of percutaneous osteosynthesis and of its performance in a supine position, this procedure provides essential advantages for the operative treatment of polytraumatized patients.