header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Trauma

UKR FOR SPONTANEOUS OSTEONECROSIS OF THE KNEE - LONG TERM RESULTS AND SURVIVORSHIP OF THE IMPLANT IN 84 PATIENTS AT A MEAN FOLLOW-UP OF 8 YEARS

European Federation of National Associations of Orthopaedics and Traumatology (EFORT) - 12th Congress



Abstract

Background

The reported outcomes of unicompartmental knee replacement (UKR) for spontaneous osteonecrosis of the knee (SPONK) often derive from small series with an average followup of 5 years, enabling to generate meaningful conclusions. Therefore, we determined the long-term functional results and the 10-years survivorship of the implant in all patients with advanced SPONK of the medial tibio-femoral compartment treated with a unicompartmental knee arthroplasty at our institute.

Methods

We retrospectively evaluated 84 consecutive patients with late stage SPONK. All patients received a pre-operative MRI to confirm the diagnosis, to exclude any metaphyseal involvement and to assess the absence of significative degenerative changes in the lateral and PF compartment. Mean age at surgery was 66 years and mean body mass index (BMI) was 28.9. In all cases, SPONK involved the medial compartment; in 77 cases the medial femoral condyle (MFC) was involved, while in 7 cases the pathology site was the medial tibial plateau (MTP). Radiological evaluation was conducted by 3 different radiologists and clinical evaluation according to KSS and WOMAC score was performed by 3 fellows from outside institutions, with no previous clinical contact with the patients, at a mean followup of 98 months.

Results

We found a significant improvement in VAS score for residual pain self-assessment and maximum knee flexion (p<0.0001). The 10-year Kaplan-Meier survivorship with revision for any reason as endpoint was 89%. Mean results at final observation point for global KSS and WOMAC score were 87.1 (range 45–100; standard deviation 13.8) and 12 (range 0–44; standard deviation 10.3), respectively. No patient had significant radiographic signs of osteoarthritis progression in the lateral compartment or in the patello-femoral compartment at final evaluation.

Conclusions

Our findings suggest that medial UKR performed for late stage SPONK of the medial tibio-femoral compartment in selected patients provides satisfactory long term clinical and radiographical results, with a 10-years Kaplan-Meier survivorship of the implant of 89%.