header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Functional outcome following revision knee arthroplasty: the role of constraint and indication for surgery

British Orthopaedic Association/Irish Orthopaedic Association Annual Congress (BOA/IOA)



Abstract

Purpose

Although classic teaching holds that the least amount of constraint should be implanted, there is very little in the literature to substantiate this. This study attempts to quantify the influence of constraint and various indications upon functional outcome following aseptic first time revision knee arthroplasty. The null hypothesis was that the level of constraint and indication for surgery would not influence the functional outcome following revision knee replacement.

Methods

A single centre prospective study was performed to examine the outcome for 175 consecutive total revision knee replacements performed between 2003 and 2008 with a minimum follow-up of two years. Patient reported outcome data was used to determine the influence of final level of component constraint and its relationship with primary indication for surgery.

Results

All patients were found to have a significant improvement for WOMAC pain, function and stiffness score (p< 0.001) and physical functioning, role physical, bodily pain and social functioning components of SF-36 score (p< 0.05). 69% were satisfied with the overall procedure. WOMAC function, pain and stiffness score was significantly worse for patients revised for instability (27%) compared to that for aseptic loosening (46%). A significantly higher proportion of patients were satisfied with the procedure (p< 0.001), had a better quality of life (p=0.004) and would have the surgery (p=0.005) again in the aseptic loosening group as compared to the instability group. Revision to a higher level of constraint did not improve knee function irrespective of the primary indication for surgery.

Conclusion

Revision for an instability pattern irrespective of choice of new device was met with significantly poorer functional outcome.