Management of hip instability with a cemented, constrained acetabular component

British Orthopaedic Association/Irish Orthopaedic Association Annual Congress (BOA/IOA)



Abstract

We evaluated the use of a cemented Constrained Acetabular Component to treat recurrent or potential instability after hip replacement. Over a seven year period, 109 patients who had undergone 110 operations were identified from hospital records. Patients were reviewed based on clinical and radiological follow-up. Post-operative mobility and quality of life was assessed using the Oxford Hip Score (OHS) and SF-12.

From an original cohort of 109 patients, 9 patients were lost to follow up. Of the remaining 100 patients, the mean follow up was 2.9 years (SD+/−2 years). There were 4 failures, requiring 3 further revisions. The mean post-operative OHS was 33, SF-12 PCS 34 and SF12 MCS 52. 5-year survivorship was 90%. Cementing a Constrained Acetabular Component provides satisfactory mid term results in patients at high risk of hip dislocation.