header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Spine

INTRODUCTION OF EGGSHELL TECHNIQUE MINIMISED THE INCIDENCE OF CEMENT LEAK DURING PERCUTANEOUS BALLOON KYPHOPLASTY PROCEDURES

British Association of Spinal Surgeons (BASS)



Abstract

Purpose

To evaluate the complications following percutaneous balloon kyphoplasty and assess the advantage of introducing eggshell technique.

Methods and Results

We performed 138 Balloon kyphoplasty procedures in 85 patients during august 2007 to march 2010. Data was collected and analyzed in all these cases. Gender distribution was 60 females and 25 males. Age distribution was 33 to 85 years, with an average age of 67.4 years. Indications of surgery were vertebral fractures due to osteoporosis in 81% of the procedures, trauma in 13% and malignancy in 6%. The most common vertebral levels of the kyphoplasty were at T12 in 32 procedures (23%) and L1 in 28 procedures (20%). Eggshell technique was introduced in 2009 where technical problems were encountered during cementing process.

All patients had reduced pain levels, which was assessed by visual analog score. The average length of hospital stay was 2.5 days. Complications were 9 (6.5%) cement leaks (all within one cm from the vertebral body) in procedures performed before the introduction of eggshell technique and no cement leak following the introduction of eggshell technique, 5 (3.6%) fresh fractures, 2 (1.4%) intra-operative fractures and 1 (0.73%) rupture of balloon. There were no complications of cord compression, motor deficit, infection, allergy to cement or pulmonary embolism noted. 30-day mortality rate was zero.

Conclusion

Our series had 6.5% incidence of cement leak compared to 11-21% quoted in current literature. Since the introduction of eggshell technique, cement leak rate was reduced to zero%.

Hence adopting of eggshell technique during percutaneous balloon kyphoplasty procedure may eliminates the risk of cement leak thereby minimizing complications.