Abstract

Purpose of the study

Release of tight lateral structures is an integral part of balancing the valgus knee during knee replacement surgery. The posterolateral capsule is released through an inside-out technique. The common peroneal nerve is in close proximity to the capsule during this step. This study was undertaken to determine the distance of the nerve and the safe level for the posterolateral release.

Methods

MR scans of the knee of 100 patients were evaluated. The age range of selected patients was 50 to 70 years. The distance of the nerve was measured to the closest point on the posterolateral capsule. Two separate measurements were taken - one 9mm above the joint line indicating the distal femoral resection level and the other 9mm distal to the joint line indicating the level of tibial resection. A third point was at the joint line level. The position of the nerve was also recorded in relation to the cross section of the femur/tibia on a ‘clock-like’ reference.

Results

The mean distance of the nerve from the capsule was 13.4mm at level of distal femoral resection, 12.4mm at the level of the joint line and 10.9mm at the level of tibial resection. The minimum distance was 8.2mm at the proximal level, 6.7mm at the level of joint line and 4.7mm at the distal level.

Conclusions

The common peroneal nerve is in close proximity to the resected femur and tibia in knee replacement surgery. The posterolateral capsular release should be done at the level of distal femoral resection using electrocautery to minimise risk of damage to the nerve.