header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Knee

EARLY TOURNIQUET RELEASE IN TOTAL KNEE REPLACEMENT: THE INFLUENCE OF RIVAROXABAN

British Association for Surgery of the Knee (BASK)



Abstract

Purpose

This study investigates the effect of early tourniquet release on range of flexion following total knee replacement, and the influence of anticoagulation with Rivaroxaban and Clexane (Enoxaparin).

Method

78 patients were included in the study, who underwent unilateral primary total knee replacement (TKR) in our department under the care of two specialist knee surgeons over a 12 month period. 27 patients underwent TKR with early release of the tourniquet and haemostasis, prior to closure of quadriceps layer: 22 were anticoagulated with Rivaroxaban (GROUP ER), 15 with the low molecular weight heparin Clexane (GROUP EC). Over the same time period, 41 patients TKR with late release of the tourniquet, following closure and bandaging: 13 were anticoagulated with Rivaroxaban (GROUP LR), 28 with Clexane (GROUP LC). A standardised operative technique was employed, and all patients received an AGC (Biomet) PCL-retaining prostheses. Outcome was assessed with range of flexion at 12 weeks postoperatively.

Results

The mean range of flexion at 12 weeks was 106.8° in Group ER, 96.54° in Group LR, 108.33° in Group EC and 101.11° in LC. The mean difference in flexion at 12 weeks between Group EC and LC was 7.2°, and between ER and LR was 10.2°.

Conclusion

Our study supports the theory that early tourniquet release and haemostasis has a beneficial effect on the early range of flexion following TKR. This affect appears to be increased when the oral anticoagulant Rivaroxaban is used, when compared with low molecular weight heparin.