COMPARISON OF METAL IONS IN PATIENTS AFTER TOTAL HIP OR TOTAL KNEE ARTHROPLASTY: A STRATIFIED RANDOMISED PROSPECTIVE CLINICAL STUDY

Australian Orthopaedic Association Limited (AOA)



Abstract

Introduction

There has been much discussion in the literature concerning the possible detrimental effects of metal ion circulating in the body after MOM THR. This study seeks to evaluate the differences in observed Co and Cr levels in blood after TKR and several popular THR options.

Method

We compared chromium (Cr) and cobalt (Co) levels between three different hip replacement bearings and total knee replacements (TKR) over time. Blood samples were taken from patients who received metasul 28 mm (n=25), metasul 32 mm (n=25) and Durom (n=50) hip bearings and TKR (n=100), pre- operatively and post operatively at six, twelve and twenty-four month intervals. Blood samples were analysed for Co and Cr levels using ICPMS (Inductively coupled mass spectrometry) and reported as parts per billion. Results were compared using Kruskal-Wallis Test (nonparametric ANOVA).

Results

No increase was seen in serum Co and Cr levels in TKR patients over time. There were statistically significant differences in Co levels between the TKR group and all bearing surfaces of THR (28, 32 mm and Durom), p<0.001 at two years. Cr levels were significantly higher (p<0.001) in Durom bearings vs TKR only at one year decreasing to p<0.01 at two years. Comparing ion levels over time in the hip group, only in the Durom cohort did serum Cr levels preop vs 12 and 24 months reach a statistical significance of p<0.001. For Co, all three bearings showed a statistically significant increment over time (p<0.01). Highest levels of ions were seen with the 28 mm bearings but comparison between the three THR bearings at two years showed no statistical difference in Cr or Co levels. Median blood Cr concentration did not exceed 1.6 ppb in any subgroup. All median Co concentrations were below 0.8ppb.

Conclusions

Over a two-year period Co and Cr levels for TKR did not differ appreciably from preoperative levels. Both Cr and Co levels were only mildly elevated post THR for all bearings. Metasul 28 mm bearings require further follow-up as the Co levels were not seen to plateau at two years.