header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

IMPROVING SURGICAL PRECISION: THE ROLE OF CONTINUOUS SURVEILLANCE TIP APEX DISTANCE MEASUREMENTS IN A DISTRICT GENERAL HOSPITAL

British Orthopaedic Specialists Association (BOSA)



Abstract

Awareness that minimising tip apex distance (TAD) when inserting a sliding hip screw reduces the risk of screw cut out is important for orthopaedic trainees. The advent of the Picture Archive and Communication System (PACS) has made the accurate measurement of TAD from x-rays and image intensifier films much easier. This study was to determine whether TAD would be reduced if a surgeon knew that his performance was being continually monitored.

31 consecutive cases of sliding hip screw insertion by a single group of surgeons were identified and the TAD measured. The mean TAD was 16.11mm (8.87mm-25.47mm). The same surgeons were then re-educated as to the importance of the TAD and informed that their results would be monitored and discussed. The next 34 consecutive cases were collected prospectively. The mean TAD in these cases was 13.83mm (6.72mm-21.51mm). There was a significant difference between the TAD for the two groups using the two-tailed t-test (p=0.034). There was one implant failure in the pre education group and none in the post education group.

These results suggest that awareness of surveillance improves surgical performance even if the importance of the variable being assessed is already known.