EARLY EXPERIENCE USING EXTREME LATERAL INTERBODY FUSION TECHNIQUE IN LUMBAR DEGENERATIVE DISEASE

Britspine, British Scoliosis Society (BSS), Society for Back Pain Research (SBPR), British Association of Spine Surgeons (BASS)



Abstract

To assess adverse events related to XLIF approach in lumbar degenerative disease.

Recently novel minimally disruptive spine procedure eXtreme lateral Interbody Fusion i.e XLIF has been developed. It is 90 (off the midline true lateral approach, which allows large graft placement, excellent disc height restoration and indirect decompression at the stenotic motion segment. We describe our experience in 28 patients.

Retrospective review of records of patients undergoing surgery between July 2008- Jan 2010. Presenting complaints, number of levels performed and complications (medical, approach, or implant related) were audited.

Results: 28 patients (17 female: 11 male) with median age of 47 yrs, range (38-75) formed the study group. Average stay was 4 days. All patients had MRI of lumbar spine. 2/3 rd patients had low back pain as their presenting complaint. All patients had nerve monitoring through out the procedure. There were 12 single, 15 two level and 1 three level cases (total 45 levels). 14/28 patients underwent plating at the same time. EBL was 100ml. There were 11/45 adverse events (24.4%). 6 events were approach, 4 were implant bone interface and 1 medical related. Major complication occurred in 1 patient (3.6%).

2/3 rd of patients, were better after the surgery. Almost negligible blood loss, low infection rate and short average stay seemed to work in favour of this approach. Complications are there as (with any new procedure) our results indicate, but these are manageable and less common with this technique.

This did not require Ethics approval and there was no grant or industry support for the above.