header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Spine

ATLANTO-AXIAL FUSION USING C1 LATERAL MASS AND C1/2 TRANARTICULAR SCREWS IN A RHEUMATOID POPULATION

Britspine, British Scoliosis Society (BSS), Society for Back Pain Research (SBPR), British Association of Spine Surgeons (BASS)



Abstract

To define how pre-operative evaluation guides surgical planning in patients with atlanto-axial subluxation secondary to rheumatoid arthritis and to measure clinical outcome for the same group.

Prospective evaluation of a consecutive cohort of 26 patients undergoing C1/2 fusion over 5 years (2004-2009).

Pre-operative evaluation of posterior atlanto-dens interval (PADI), C1 lateral mass and C2 pedicle dimensions.

Pre- and post-op Ranawat scores and visual analogue scores for neck and C2 pain

C1/2 instability resulted from rheumatoid arthritis (21), trauma (4) and infection (1).

C1 lateral mass mean height 4.4mm, C2 pedicle mean height 5.1mm and mean width 3.4mm (30% width <3mm).

Ranawat scale improved Grade II to Grade I (p=0.07). Neck pain (pre-op mean 5.5, s.d. 2.8; post-op mean 1.6, s.d. 2.1, t<0.05) and C2 pain (pre-op mean 2.1, s.d. 3.3; post-op mean 0.5, s.d. 1.2, t<0.05) improved.

No instrumentation failure. In the rheumatoid group, 17/21 patients had C1 lateral mass and C1/2 transarticular screws. 1 patient had a cranio-cervical fusion and 3 patients had other constructs.

3 patients had C2 numbness. No other neurological deficit.

In a rheumatoid population, pre-operative evaluation often precludes the use of C2 pedicle screws. Rigid fixation with a C1 lateral mass and C1/2 transarticular polyaxial screw-rod system is associated with good clinical outcomes.