THE MIDTERM RESULT OF A SECOND GENERATION METAL-ON-METAL TOTAL HIP ARTHROPLASTY FOR THE TREATMENT OF OSTEONECROSIS OF THE FEMORAL HEAD IN YOUNGER PATIENTS

Yokohama, Japan, November 2009 meeting



Abstract

Introduction

The purpose of this study was to evaluate the functional and radiographical mid-term follow-up results of a second generation metal-on-metal cementless total hip arthroplasty for the treatment of osteonecrosis of the femoral head in patients younger than 50 years.

Methods

Twenty eight patients (35 hips) who underwent total hip arthroplasty with second generation metal-on-metal bearings for osteonecrosis of the femoral head at a minimum 5-year follow-up were included in this study. There were 5 women (6 hips) and 23 men (29 hips) who had a mean age of 40 years (range, 23 to 49 years) and a mean follow-up of 7 years. We used a Fitmore (Zimmer) cup and a 28mm Metasul femoral head in all cases. A CLS (Protek AG/Zimmer) femoral stem was used in 30 hips and a Cone prosthesis¯ (Protek AG) was used in 5 hips. Functional results were measured by Harris hip (HHS) and WOMAC scores. Radiographic evaluations were used to assess loosening and osteolysis according to Gruen and Delee and Charnley criteria.

Results

The mean Harris hip score improved from 58 points (range, 35 to 67 points) pre-operatively to 92 points (range, 84 to 99 points) post-operatively, and the mean WOMAC score improved from 73 points (range, 63 to 89 points) to 30 points (range, 24 to 41 points). On radiological evaluation, all femoral and acetabular components were well-fixed without loosening or subsidence. Osteolysis was observed in 5 hips (14%) (acetabular osteolysis in 2 cases-Zone 2; 1, Zone 3; 1, femoral osteolysis in 3 cases- Zone 1; 2, Zone 7; 1). There were no complications including immediate post-operative deep infection, delayed infection, or recurrent dislocation. There was no case of revision for aseptic loosening.

Conclusion

Second generation metal-on-metal cementless total hip arthroplasty for the treatment of osteonecrosis of the femoral head in patients younger than 50 years showed favorable functional and radiographic results.