REVIEW OF 2440 CEMENTED ANATOMICAL AGC TOTAL KNEE REPLACEMENTS AT A SINGLE INSTITUTION - REVISION RATES AND FUNCTIONAL OUTCOME SCORES

British Association for Surgery of the Knee (BASK)



Abstract

We prospectively reviewed 2440 Cemented Anantomical (side specific) AGC total knee replacements performed on 2074 patients between 2002 and 2008 in our unit. The surgery was performed by a number of surgeons, both Consultant and Trainee grades. 1357 underwent PCL sacrificing surgery with implantation of Posterior Stabilised Femoral Implant (Cam and Grove) and 1083 underwent PCL retaining surgery with implantation of a Non-Stabilised Femoral Implant. The mean age at date of surgery for Posterior Stabilised prosthesis was 69 years (range 23-94) and Non-Posterior Stabilised prosthesis was 70 (range 33-97) with no significant difference p< 0.05 (C.I 95%). Follow up at present mean 4 years (range 1-6 years).

11 patients underwent secondary patella resurfaced for anterior knee pain at a mean of 1.5 years following the index procedure (range 0.5-4.1 years) with 6 patients reporting a marked improvement in anterior knee pain post operatively. 3 patients underwent removal of patella buttons for symptomatic loosening at a mean of 2.7 years follow index procedure.

A total of 17 patients underwent a revision of either tibial or femoral components (0.7%). Indications for revision were infection in 11 patients, gross instability in 1 patient, periprosthetic fracture in 1 patient, persistent stiffness in 1 patient. 3 patients underwent revision for symptomatic loosening of the tibial component at a mean of 2.9 years (range 1.1-4.0).

These short to medium term results for the Anatomic AGC total knee replacement agree with published results from other centres.