header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

VOLAR PLATE FIXATION OF COMPLEX DISTAL RADIAL FRACTURES WITH THE ITS PLATE

British Orthopaedic Association (BOA) 2005



Abstract

The ITS volar radial plate (Implant Technology Systems, Graz/Austria) is a fixation device that allows for the distal locking screws to be fixed at variable angles (70°-110°). This occurs by the different material properties, with the screws (titanium alloy) cutting a thread through the plate holes (titanium). We present our experience with the ITS plate.

We retrospectively studied 26 patients who underwent ITS plate fixation for unstable multifragmentary distal radial fractures (AO types A3, B2, B3, C2, C3). The surgery was performed either by a consultant orthopaedic hand surgeon or senior registrar. A volar approach was used every time and 10 cases required synthetic bone grafting. Post-operatively they were immobilised for an average of 2.5 weeks.

The 26 patients had a mean age of 58 and the dominant side was affected in 46% of cases. 5 cases were open fractures and 10 cases followed failed manipulation under general anaesthesia. The average interval between injury and surgery was 7 days. Union was achieved in all cases. No implant infections, failure or tendon rupture/irritation occurred. There were two fractures which loss reduction, of which one required revision surgery. There was one case of CRPS. The six month average DASH score was 27.5.

We consider the ITS plate a technically easy plate to use and a reliable implant at early follow-up. We value the versatility of its variable angle screw fixation ability for complex intra-articular distal radial fractures.