MEDIUM-TERM OUTCOMES FOLLOWING STEMLESS ANATOMIC TOTAL SHOULDER ARTHROPLASTY: CLINICAL AND RADIOLOGICAL FINDINGS (MINIMUM FIVE-YEAR FOLLOW-UP)

The Scottish Committee for Orthopaedics and Trauma (SCOT) Meeting, Crieff, Scotland, 19 January 2024.



Abstract

In recent years, use of anatomic stemless total shoulder arthroplasty (AsTSA) has increased. Despite evidence to suggest good mid-term results at 2-year follow-up there is a paucity of evidence for longer term follow-up. This study aimed to investigate outcomes at a minimum of 5 years post-operatively following primary AsTSA.

This study is a retrospective case series of all patients who underwent a Mathys Affinis AsTSA from July 2010 (first case) to August 2018 (to allow minimum 5-year follow-up). Clinical outcomes included revision rate, range of motion and patient reported outcomes (Oxford Shoulder Score and Numerical Satisfaction Score). Radiological outcome was assessment of radiolucent lines for Lazarus grading.

A total of 105 stemless TSAs were implanted. Five patients underwent revision (4.8%). Seventy-five AsTSA's were included in the final study for analysis of 5-year outcomes. Median follow-up time was 6.1 years. Median age was 69 years old and 81% were female. Oxford shoulder score showed a range of 18 to 48, with a median score of 47. Satisfied or very Satisfied was selected in 94.37%. Median range of motion assessments showed forward elevation 160°, abduction 150°, external rotation 40°, and mode internal rotation was to the lumbar spine. No glenoid lucency was present in 79.7%. There were 9.5% with Lazarus Grade 1 lucency, 5.4% with Lazarus Grade 2, and 5.4% Lazarus Grade 3. No humeral lucency was observed.

This cohort study demonstrates promising clinical and radiological outcomes for the Mathys Affinis Stemless TSA at minimum 5 years post-operatively.