RELATIONSHIP OF THE TRICEPS TENDON AND OLECRANON PLATES: AN ANATOMIC STUDY

The International Combined Orthopaedic Research Societies (ICORS), World Congress of Orthopaedic Research, Edinburgh, Scotland, 7–9 September 2022. Part 2 of 3.



Abstract

Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon.

Eight cadaveric elbows were used. Dimensions of the triceps tendon at the insertion and 1cm proximal were measured. A long or a short olecranon plate was then applied over the olecranon and the most proximal screw applied. The length of the plate impinging on the tendon and the level of the screw tract on the tendon and bone were measured.

The mean olecranon height was 24.3cm (22.4-26.9cm) with a tip-to-tendon distance of 14.5cm (11.9-16.2cm). The triceps tendon footprint averaged 13.3cm (11.7-14.9cm) and 8.8cm (7.6-10.2cm) in width and length, respectively. The mean width of the central tendon 1 cm proximal to the footprint was 6.8 cm. The long olecranon plate overlay over more movable tendon length than did the short plate and consequently the superior screw pierced the triceps tendon more proximally with the long plate. Using the Mann-Whitney U test, the differences were significant.

The long olecranon plates encroach on more triceps tendon than short plates. This may be an important consideration for olecranon fractures with regards implant loosening or triceps tendon injury.


Email: