REMOVAL OF PRESS-FIT TRANSTIBIAL OSSEOINTEGRATION IMPLANTS

The British Limb Reconstruction Society (BLRS) Annual Meeting 2023, Belfast, Northern Ireland, 23–24 March 2023.



Abstract

Introduction

Approximately 2,000 Skeletal transcutaneous osseointegration (STOI) procedures have been performed worldwide as of 2020, more than half of which have been performed by the Osseointegration Group of Australia using a press-fit technique with either ILP or OPL implant designs. Despite the consistently demonstrated clinical benefits, concerns regarding potential complications following STOI have slowed its widespread adoption. As more patients are followed for a longer period of time, longitudinal studies have confirmed complication rates are very acceptable, similar to those of total ankle and total elbow replacements. One of the major risk category is implant removal. The primary goal of this study was to investigate the complications and technical issues associated with transtibial osseointegration implant removal due to any cause. The focus here will be on the press-fit ILP and OPL implants, including the indications for removal and patient outcomes following removal.

Materials & Methods

A review of our osseointegration registry between November 2010 and March 2022 was performed. Inclusion criteria were patients who have undergone removal of a transtibial osseointegration implant due to any cause. Selected patients either had a follow-up of at least two years or had their index osseointegration surgery at least two years prior to when the study was performed. Patients who have had osseointegration at other anatomic levels, and patients who underwent simultaneous total knee replacement with transtibial osseointegration were excluded from the registry search.

Results

There were a total of 148 transtibial osseointegration procedures performed during the study period, with 97 (65.5%) performed in males and 51 (34.5%) performed in females. The average age at first stage osseointegration procedure is 50.4 years (range 16.8–87.9, SD 14.1). In the study cohort of 22 cases requiring implant removals, 12 (54.5%) were male and 10 (45.5%) were female. The average age at first stage osseointegration procedure in this cohort is 51.3 (range 37.4–82.6, SD 10.7) and average BMI 30.3 (range 21.9–40.9, SD 5.8). Although men comprised the majority of removals, women had a greater relative risk (Fisher exact test p=0.032). The average duration from time of STOI to removal was 2.6 years (range 0.1–6.8, SD 1.9) within this 11.5 year follow-up period. The most frequent indication was infection (54.6%, n=12) followed equally by pain (13.6%, n=3), aseptic loosening (13.6%, n=3) and implant fracture (13.6%, n=3), and lastly failure to integrate (4.6%, n=1).

Conclusions

Of the 22 removals, 12 were reimplanted at the same anatomical level (10 were reimplanted within 6 months, 1 within 12 months, and 1 within 24 months). 11 of these cases currently wear their prosthetic legs for more than 13 hours daily. 1 case was recently reimplanted and still completing their loading program. Of the patients who were not reimplanted at the same anatomical level, 1 required proximal amputation with transfemoral osseointegration. 3 patients converted to traditional socket prostheses (TSP) due to pain, and 1 underwent proximal amputation and converted to TSP due to infection. 3 cases are currently awaiting transtibial osseointegration reimplantation, and 1 patient was deceased. 1 patient was lost to follow-up.