header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

SIX PERCENT INCIDENCE OF GRAFT-TUNNEL MISMATCH IN ANATOMIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING BONE-PATELLA TENDON-BONE AUTOGRAFT AND ANTEROMEDIAL PORTAL DRILLING

The Canadian Orthopaedic Association (COA) and Canadian Orthopaedic Research Society (CORS) Annual General Meeting, Quebec City, Quebec, Canada, 8–11 June 2022. Part 2 of 2.



Abstract

The purpose of this study was to determine the incidence of graft-tunnel mismatch (GTM) when performing anatomic anterior cruciate ligament reconstruction (ACLR) using bone-patella tendon-bone (BPTB) grafts and anteromedial portal drilling.

Beginning in November 2018, 100 consecutive patients who underwent ACLR by two sports fellowship-trained, orthopedic surgeons using BPTB autograft and anteromedial portal drilling were prospectively identified. The BPTB graft dimensions and the femoral tunnel distance, tibial tunnel distance, intra-articular distance, and total distance were measured. Surgeons determined the depth and angle of tunnels based on the patella tendon graft length dimensions in each case. After passage of the graft, the distance from the distal graft tip to the tibial cortex aperture was measured. GTM was defined as the need for additional measures to obtain satisfactory tibial graft fixation (< 1 5e20 mm of bone fixation).

The incidence of mismatch was 6/100 (6%). Five cases involved the graft being too long, with the tibial bone plug protruding excessively from the tibial tunneld4/5 had a patella tendon length ? 50 mm. Three cases were managed with femoral tunnel recession, and two were treated with a free bone plug technique. One patient with a patella tendon length of 35 mm had a graft that was too short, with the tibial bone plug recessed in the tibial tunnel. Of patients whose tibial tunnel distance was within 5 mm of the patella tendon length, only 1/46 (2%) patients had mismatch, whereas 5/54 (9%) of patients who had >5 mm difference had mismatch.

The incidence of grafttunnel mismatch after anatomic ACLR using BTPB and anteromedial portal drilling in this study is 6%. To limit the occurrence of GTM where the graft is too long, surgeons should drill tibial tunnel distances within 5 mm of the patella tendon length.


Email: