Objectives

Operative management of distal humerus fractures is challenging. In the past, plates were manually contoured intraoperatively, however this was associated with high rates of fixation failure, nonunion and metalwork removal. Anatomically pre-contoured distal humerus locking plates have since been developed. Owing to the rarity of distal humeral fractures, literature regarding outcomes of anatomically pre-contoured locking plates is lacking and patient numbers are often small. The purpose of this study is to investigate the outcomes of these patients.

Methods

We retrospectively identified patients with distal humeral fractures treated at our institution from 2009–2018. Inclusion criteria were patients with a distal humeral fracture, who underwent two-column plate fixation with anatomically pre-contoured locking plates. Clinical records and radiographs were reviewed to elicit outcome measures, including range of motion, complications and reoperation rate.

Results

We identified 50 patients with mean age of 55 years (range 17–96 years). Mean length of follow up was 5.2 years. AO fracture classification Type A occurred most frequently (46%), followed by Type B (22%) and Type C (32%). Low energy mechanisms of injury predominated in 72% of patients. Mean time from injury to fixation was seven days. Mean range of motion at the elbow was 13–123o postoperatively. The overall reoperation rate was 22%, the majority of which required subsequent removal of prominent metalwork (18%). The incidence of nonunion, heterotopic ossification, deep infection and neuropathy requiring decompression was 2% each. Fixation failure occurred in only one patient however the fracture went on to heal.

Conclusions

Previously reported reoperation rates with manually contoured plates were as high as 44%, which is twice our reported rate. Modern locking plates are no longer subject to implant failure (previously 27% reported metalwork failure rate). Likewise, heterotopic ossification and non-union have also reduced, highlighting that modern plates have significantly improved overall patient outcomes.

Declaration of Interest

(b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project.