Introduction and Objective

When using radiation intraoperatively, a surgeon should aim to maintain the dose as low as reasonably achievable to obtain the diagnostic or therapeutic goal. The UK Health Protection Agency reported mean radiation dose-area-product (DAP) of 4 Gy cm2 for hip procedures. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.

Materials and Methods

We assessed 369 neck of femur fractures between April 2019 and April 2020 in one district general hospital. Fractures were classified as extracapsular or intracapsular and into subtypes as per AO classification. Data was collected on type of fractures, implants used, level of surgeon, duration of surgery and DAP. Types of fractures were subclassified as complex (multifragmentary, subtrochanteric and reverse oblique) or simple.

Results

Patients with fractures fixed with DHS, short PFNA, long PFNA and cannulated screws were included. 50% of our patients were fixed with hemiarthroplasty or total hip replacement and were therefore excluded. 184 patients were included in the analysis. There was a significant association of higher DAP with fracture subtype (P=0.001), fracture complexity (P<0.001), if an additional implant was used (P=0.001), if fixation was satisfactory (P=0.002) and the operative time (P<0.001). DAP was higher in PFNA than DHS and greatest in Long PFNA. There was some evidence of association between the level of the surgeon and DAP, although this was not statistically significant (P=0.069) and remained not significant after adjusting for the variables (fracture complexity, fixation or implant used) (p=0.32).

Conclusions

Increased radiation in proximal femur fractures is seen in fixation of complex fractures, certain subtypes, the type of implant used and if an additional implant was required. Seniority of surgeon did not result in less radiation exposure even when adjusting for other factors, which is in contrast to other published studies.