Full Access

Hip

COMPUTER-GUIDED TOTAL HIP ARTHROPLASTY IS ASSOCIATED WITH A REDUCED RISK OF REVISION AND INCREASED PATIENT SATISFACTION: AN ANALYSIS OF A SINGLE MANUFACTURER ACETABULAR COMPONENTS FROM THE NATIONAL JOINT REGISTRY OF ENGLAND, WALES, NORTHERN IRELAND, AND THE ISLE OF MAN

British Hip Society (BHS) meeting, held online, 9–11 June 2021.



Abstract

Computer aided Total Hip Arthroplasty (THA) surgery is known to improve implantation precision, but clinical trials have failed to demonstrate an improvement in survivorship or patient reported outcome measures (PROMs). Our aim was to compare the risk of revision, PROMs and satisfaction rates between computer guided and THA implanted without computer guidance.

We used the National Joint Registry dataset and linked PROMs data. Our sample included THAs implanted for osteoarthritis using cementless acetabular components from a single manufacturer (cementless and hybrid). An additional analysis was performed limiting the sample size to THAs using cementless stems (fully cementless). The primary endpoint was revision (of any component) for any reason. Kaplan Meier survivorship analysis and an adjusted Cox Proportional Hazards model were used.

41683 non computer guided, and 871 (2%) computer guided cases were included in our cementless and hybrid analysis. 943 revisions were recorded in the non-guided and 7 in the computer guided group (adjusted Log-rank test, p= 0.028). Cumulative revision rate at 10 years was 3.88% (95%CI: 3.59 – 4.18) and 1.06% (95%CI: 0.45 – 2.76) respectively. Cox Proportional Hazards adjusted HR: 0.45 (95%CI: 0.21 – 0.96, p=0.038). In the fully cementless group, cumulative revision rate at 10 years was 3.99% (95%CI: 3.62 – 4.38) and 1.20% (95%CI: 0.52 – 3.12) respectively. Cox Proportional Hazards adjusted HR: 0.47 (95%CI: 0.22 – 1.01, p=0.053). There was no statistically significant difference in the 6-month Oxford Hip Score, EQ-5D, EQ-VAS and success rates. Patient Satisfaction (single-item satisfaction outcome measure) was improved in the computer guided group but this finding was limited by a reduced number of responses.

In this single manufacturer acetabular component analysis, the use of computer guided surgery was associated with a significant reduction in the early risk of revision. Causality cannot be inferred in view of the observational nature of the study, and further database and prospective studies are recommended to validate these findings.