LONG-TERM RESULTS OF TRIPOLAR CONSTRAINED TOTAL HIP ARTHROPLASTY: A MINIMUM FOLLOW UP OF TEN YEARS

The Canadian Orthopaedic Association (COA) and The International Combined Orthopaedic Research Societies (ICORS) Meeting, Montreal, Canada, June 2019.



Abstract

Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate.

The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute.

We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1998 and 2008. Eighty-nine were revised due to recurrent dislocations, 11 for pseudotumor with dysfunctional abductors, and 13 for periprosthetic infection with loss of soft tissue stabilizers. All patients had revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 had more than 3 revisions. We extracted demographics, implant data, rate of dislocations and incidence of other complications. Kaplan Meier curves were used to assess dislocation and failure for any reason. WOMAC was used to assess quality of life.

At 10 years, the survival free of dislocation was 95.6% (95%CI 90- 98), and at 20 years to 90.6% (95% CI 81- 95.5). Eight patients (7.1%) had dislocations of their constrained liners: 1 patient had simultaneous periprosthetic infection identified at the time of open reduction, and 1 patient sustained stem fracture 3 months prior to the liner dislocation. At 10 years, the survival to any further surgery was 89.4% (95% CI 82–93.8), and at 20 years, this was 82.5 (95% CI 71.9–89.3). Five patients (4.4%) had deep infection: 4 of these had excision arthroplasty due to failure to control infection, while 1 patient was treated successfully with debridement, exchange of mobile components and intravenous antibiotics. Two patients (1.8%) had dissociated rings that required change of liner, ring and head. Two patients (1.8%) had periprosthetic femoral fractures that were treated by revision stems and exchange of constrained liners. The mean WOMAC functional and pain scores were 66.2 and 75.9 of 100, respectively.

Constrained tripolar liners in our institute provided favourable results in the long term for recurrent dislocation hip arthroplasty with dysfunctional hip stabilizers. Infection in these patients can prove to be difficult to treat due to their poor soft tissue conditions from repeated surgeries. Comparing long terms results from other types of constrained liners is essential to evaluate these salvage liners.