Abstract

Summary

The mathematical model has proven to be highly accurate in measuring leg length before and after surgery to determine how leg length effects hip joint mechanics.

Introduction

Leg length discrepancy (LLD) has been proven to be one of the most concerning problems associated with total hip arthroplasty (THA). Long-term follow-up studies have documented the presence of LLD having direct correlation with patient dissatisfaction, dislocation, back pain, and early complications. Several researchers sought to minimize limb length discrepancy based on pre-operative radiological templating or intra-operative measurements. While often being a common occurrence in clinical practice to compensate for LLD intra-operatively, the center of rotation of the hip joint has often changes unintentionally due to excessive reaming. Therefore, the clinical importance of LLD is still difficult to solve and remains a concern for clinicians.

Objective

The objective of this study is two-fold: (1) use a validated forward-solution hip model to theoretically analyze the effects of LLD, gaining better understanding of mechanisms leading to early complication of THA and poor patient satisfaction and (2) to investigate the effect of the altered center of rotation of the hip joint regardless LLD compensation.

Methods

The theoretical mathematical model used in this study has been previously validated using fluoroscopic results from existing implant designs and telemetric devices. The model can be used to theoretically investigate various surgical alignments, approaches, and procedures. In this study, we analyzed LLD and the effects of the altered center of rotation regardless of LLD compensation surgeons made. The simulations were conducted in both swing and stance phase of gait.

Results

During swing phase, leg shortening lead to loosening of the hip capsular ligaments and subsequently, variable kinematic patterns. The momentum of the lower leg increased to levels where the ligaments could not properly constrain the hip leading to the femoral head sliding from within the acetabular cup (Figure 1). This piston motion led to decreased contact area and increased contact stress within the cup. Leg lengthening did not yield femoral head sliding but increased joint tension and contact stress. A tight hip may be an influential factor leading to back pain and poor patient satisfaction.

During stance phase, leg shortening caused femoral head sliding leading to decreased contact area and an increase in contact stress. Leg lengthening caused an increase in capsular ligaments tension leading to higher stress in the hip joint (Figure 2).

Interestingly, when the acetabular cup was superiorized and the surgeon compensated for LLD, thus matching the pre-operative leg length by increasing the neck length of the femoral implant, the contact forces and stresses were marginally increased at heel strike (Figure 3).

Conclusion and Discussion

Altering the leg length during surgery can lead to higher contact forces and contact stresses due to tightening the hip joint or increasing likelihood of hip joint separation. Leg shortening often lead to higher stress within the joint. Further assessment must be conducted to develop tools that surgeons can use to ensure post-operative leg length is similar to the pre-operative condition.

For any figures or tables, please contact authors directly.