header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

THE EFFECT OF IMPACTED ALLOGENIC CHIP BONE GRAFT USAGE FOR NON-CONTAINED TYPE BONE DEFECT IN PRIMARY OR REVISION TOTAL KNEE ARTHROPLASTY

International Society for Technology in Arthroplasty (ISTA) meeting, 32nd Annual Congress, Toronto, Canada, October 2019. Part 2 of 2.



Abstract

Purpose

The aim of this study was to assess the clinical and radiological result of the usage of chip bone graft in non-contained type bone defect in primary or revision total knee arthroplasty patients.

Subjects and Methods

We investigated 32 patients who had underwent primary or revision total knee arthroplasty from March, 2014 to February, 2017 in our hospital, who had non-contained type of defect. The mean age was 73.1 years. 5 of them were males, while 27 of them were females. 7 of them were primary total knee arthroplasty patients, while 25 of them were revision patients. 8 of them had chip bone graft used both in the femur and tibia. 9 of them had chip bone graft used only in the tibia. The other 15 had chip bone graft used only in the femur. Wire-mesh was used in the 9 patients who had chip bone graft used only in the medial side of the tibia. We used KOOS (Knee injury and osteoarthritis outcome score), HSS (Hospital for Special Surgery knee service rating system) and WOMAC scores to assess the clinical result, before the surgery and at the last follow-up. In addition, we had follow-up x-rays and 3D CT done for the patients to check the mean bone union period. In addition, overall radiologic imaging studies were used for complications such as loosening, osteolysis and lesions with radiolucency.

Result

The Mean follow-up period was 2.7 years (range; 2.1 to 5). The Mean preoperative KOOS was 102.8 (range; 47 to 132), while it became 31.8 postoperatively (range; 20 to 45). The mean HSS was 13.1 (range; 6 to 35), while it became 35.9 postoperatively (range; 24 to 64). The mean WOMAC was 82.9 (range; 62 to 92), while it became 22.5 postoperatively (range; 13 to 30). According to follow-up x-ray and CT, the mean bone union period was 10.6 months (range: 10 to 13). In follow-up 3D CT of all cases, we could check cortical healing and new bone formation, seen as medium to high-attenuating conglomerate. The graft-host junction showed trabecular ingrowth, while the medullary canal showed fibrous ingrowth. Radiologically, there was no complication such as loosening, osteolysis, migration and radiolucent lines around the stems or cement mantles. In addition, there was no complication such as infection.

Conclusion

Chip bone graft is not a commonly used method for bone defect in total knee arthroplasty. According to the result of the usage of chip bone graft in primary or revision total knee arthroplasty with non-contained type of bone defect, it showed favorable result for the subject patients. Therefore, we can consider it as one of the effective methods to manage non-contained bone defect in knee arthroplasty.

Keywords

Revision TKA, chip bone graft, wire-mesh, non-contained bone defect

For any figures or tables, please contact authors directly.