Aims

Only a small number of studies exist that report the results of EBM-produced porous coated trabecular titanium cups in primary total hip arthroplasty (THA). This study aims to investigate the patient satisfaction level, clinical function and radiographic outcomes of the patients who underwent THA using an EBM-produced porous coated titanium cup.

Patients and Methods

A total of 32 patients who underwent primary THA with using an EBM-produced porous coated titanium cup from five hospitals between May and December, 2012 were retrospectively reviewed. Five patients were lost prior to the minimum 6-year follow-up. Clinical and radiographic outcomes were analyzed with an average follow-up of 81.48 (range: 77.00–87.00) months.

Results

The median HHS and SF-36 scores improved significantly while the WOMAC Osteoarthritis Index decreased significantly at the latest follow-up (p<0.001). Eighteen (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1(3.7%) as dissatisfied. No intraoperative or postoperative complications were identified, including aseptic cup loosening, hip dislocation, periprosthetic joint infection, periprosthetic fracture, nerve palsy, hematoma. At the latest follow-up, all cups were considered to have achieved fixation via bone ingrowth with three or more of the five signs occurring in the most recent X-ray. However, three cups revealed radiolucent lines with a width of less than 1 mm. These radiolucent lines were distributed in the DeLee-Charnley zone 1 in 1 patient, zone 3 in another patient and the area between zone1 and zone 2 in an additional patient. The latest postoperative centers of rotation were restored nearly to the anatomic center of rotation both vertically and horizontally and the acetabular cups obtained satisfactory orientation postoperatively.

Conclusions

The mid-term follow-up of patients who underwent primary THA using EBM-produced porous coated titanium cups demonstrated favorable patient satisfaction, clinical function and adequate biological fixation.