Abstract

The battle of revision TKA is won or lost with safe, effective, and minimally bony-destructive implant removal, protecting all ligamentous stabilisers of the knee and, most importantly, the extensor mechanism. For exposure, incisions should be long and generous to allow adequate access. A standard medial parapatellar capsular arthrotomy is preferred. A synovectomy is performed followed by debridement of all scar tissue, especially in the medial and lateral gutters. All peripatellar scar tissue is excised followed by release of scar tissue within the patellar tendon, allowing for displacement or everting of the patella. As patellar tendon avulsion at any time of knee surgery yields disastrous results, the surgeon should be continuously evaluating the patellar tendon integrity, especially while displacing/everting the patella and bringing the knee into flexion. If displacement/eversion is difficult, consider rectis-snip, V-Y quadricepsplasty, or tibial tubercle osteotomy. The long-held requisite for patellar eversion prior to component removal is inaccurate. In most cases simple lateral patellar subluxation will provide adequate exposure.

If a modular tibial system is involved, removal of the tibial polyethylene will decompress the knee, allowing for easier access to patellar, femoral, and tibial components. For patellar component removal, first identify the border of the patella, then carefully clean and debride the interface, preferably with electrocautery. If the tibial component is cemented all-polyethylene, remove using an oscillating saw at the prosthetic-bone interface. Debride the remaining cement with hand tools, ultrasonic tools, or burrs. Remove the remaining peg using a low-speed burr. If the tibial component is metal-backed, then utilise a thin saw blade or reciprocating saw to negotiate the undersurface of the component between the pegs. If pegs are peripherally located, cut with a diamond disc circular cutting tool. Use a trephine to remove the pegs.

For femoral component removal, identify the prosthetic-bone/prosthetic-cement interface then remove soft tissue from the interface, preferably with electrocautery. Disrupt the interface around all aspects of the component, using any of following: Gigli saw for cementless components only, micro saw, standard oscillating saw, reciprocating saw, a series of thin osteotomes, or ultrasonic equipment. If the femoral component is stemmed, remove the component in two segments using an appropriate screwdriver to remove the screw locking the stem to the component. Remove the femoral component with a retrodriver or femoral component extractor. Debride cement with hand tools or burr, using care to avoid bone fracture. If a stem is present, then remove with the appropriate extraction device. If “mismatch” exists, where femoral (or likewise, tibial) boss is smaller in diameter than the stem, creating a cement block prohibiting stem removal, remove the cement with hand tools or burr. If the stem is cemented, use hand tools, ultrasonic tools, or a burr to debride the cement. Curette and clean the canals.

For tibial component removal, disrupt the prosthetic-cement/prosthetic-bone interface using an oscillating or reciprocating saw. Gently remove the tibial component with a retrodriver or tibial extractor. If stem extensions are utilised, disengage and debride all proximal cement prior to removing the stem. If stem is present, then remove stem with appropriate extraction device. If stem is grit-blasted and well-fixed, create 8mm burr holes 1.5 to 2.5cm distal to tibial tray on medial aspect and a small divot using burr, then drive implant proximally with Anspach punch. Alternatively, a tibial tubercle osteotomy may be performed. If the stem is cemented, use hand tools, ultrasonic tools or burr to debride cement.