HAND-MADE ARTICULATING CEMENT SPACERS IN TWO-STAGE REVISION FOR INFECTED TOTAL HIP ARTHROPLASTY: A PROSPECTIVE COHORT STUDY

International Society for Technology in Arthroplasty (ISTA) 31st Annual Congress, London, England, October 2018. Part 1.



Abstract

Introduction

Periprosthetic joint infection (PJI) is a serious problem and requires great effort and cost for its treatment. Treatment options may vary from resection arthroplasty, retention of prosthesis with debridement, one stage revision and two stage revision with handmade antibiotic impregnated cement spacer or with prefabricated antibiotic loaded cement spacer. Two stage revision remains the gold standard for the treatment of periprosthetic joint infection after Total Hip Arthroplasty (THA). This study was aimed to find the efficacy and cost effectiveness of handmade antibiotic impregnated articulating cement spacer over commercially available prefabricated antibiotic loaded cement spacer for the treatment of deep PJI of hip prosthesis and to evaluate its functional outcome.

Material and methods

A total of 23 PJI patients were enrolled in this prospective cohort study. In the two stages of revision, the first stage consisted of thorough debridement, implant removal and implantation of handmade articulating antibiotic impregnated cement spacer. The second stage surgery consisted of removal of cement spacer, thorough debridement and implantation of new prosthesis. All patients were followed for a period of 24 months.

Results

A total of 23 patients (15 males and 8 females) underwent two stage revision arthroplasty for chronic periprosthetic joint infection. The mean age of the patient was 57 years. The handmade antibiotic impregnated cement spacer was retained for 16– 20 weeks. Common organism observed was coagulase negative staphylococci followed by Staphylococcus aureus. After an average follow up of 2 years, 20 patients with PJI remained clinically free of infection. In 2 patients there was recurrence of infection.

Conclusion

We conclude that two stage revision by hand made cement spacer is successful in eradication of infection with satisfactory functional outcome. Furthermore, these handmade cement spacer are cost effective and their efficacy may be comparable to commercially available prefabricated spacer.