header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Hip

STANDARDIZATION OF LATERAL PELVIC RADIOGRAPH IS NECESSARY TO PREDICT SPINOPELVIC MOBILITY ACCURATELY

The Hip Society (THS) 2019 Summer Meeting, Kohler, WI, USA, 25–27 September 2019.



Abstract

Introduction

Patients with abnormal spinopelvic mobility are at increased risk for hip instability. Measuring the change in sacral slope (ΔSS) with standing and seated lateral radiographs is commonly used to determine spinopelvic mobility pre-operatively. Sacral slope should decrease at least 10 degrees to demonstrate adequate accommodation. Accommodation of <10 deg necessitates acetabular component position change or use of a dual mobility implant. There is potential for different ΔSS measurements in the same patient based on sitting posture.

Methods

78 patients who underwent THA were reviewed to quantify the variability in pre-operative spinopelvic mobility when two different seated positions (relaxed sitting v. pre-rise sitting) were used in the same patient.

Results

34 patients had standardized pre-rise sitting x-rays, while 44 patients had standardized relaxed sitting x-rays. Of the 44 patients with relaxed sitting x-rays, the mean ΔSS (ΔrSS) was 20.4 degrees. No patients exhibited an increase in sacral slope when sitting (ie; reverse accommodation). Of the 34 patients with pre-rise sitting x-rays, the mean pre-rise sit-stand change (ΔprSS) was only 1.85 degrees with 47% (16/34) showing reverse accommodation, actually increasing the seated sacral slope compared to standing sacral slope. 18 patients had both pre-rise and relaxed sitting x-rays. In patients with both seated x-rays, the mean relaxed sit-stand change in sacral slope (ΔrSS) was 18.1 ± 6.1 degrees and only 3.0 ± 10.5 degrees for pre-rise sit-stand (ΔprSS), with a mean ΔSS difference of the 15.1 degrees (p <0.0001).

Conclusion

A 15 degrees error could be made in pre-operative planning depending on the seated posture of the patient. Since decisions on component position or use of dual-mobility are made on pre-operative lateral sit-stand radiographs, postural standardization is critical. The relaxed seated radiograph is the preferred posture at the time of the seated lateral radiograph.

For any tables or figures, please contact the authors directly.