NOVEL THEORETICAL ASSESSMENT OF CUP POSITIONING AND JOINT STABILITY IN TOTAL HIP ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 30th Annual Congress, Seoul, South Korea, September 2017. Part 2 of 2.



Abstract

Background

Extensive research has previously been conducted analyzing the biomechanical effects of rotational changes (i.e. version and inclination) of the acetabular cup. Many sources, citing diverse dislocation statistics, encourage surgeons to strive for various “safe zones” during the THA operation. However, minimal research has been conducted, especially under in vivo conditions, to assess the consequences of cup translational shifting (i.e. offsets, medial and superior reaming, etc.). While it is often the practice to medialize the acetabular cup intraoperatively, there is still a lack of information regarding the biomechanical consequences of such cup medializations and medial/superior malpositionings.

Objective

Therefore, the objective of this study is to use a validated forward solution mathematical model to vary cup positioning in both the medial and superior directions to assess simulated in vivo kinematics.

Methods

The model used for this study has been validated with telemetric data and incorporates numerous muscles and ligaments. The model is parametrically derived and allows the user to simulate a theoretical THA surgery and to assess the outcomes of proper positioning as well as malpositioning of the cup. Parameters of interest in this study are component positions, joint instability and sliding, and contact area.

Results

An intraoperative representation of the pelvis and cup was assessed (Figure 1), with a green star showing the native anatomical center, the red circle showing the acetabular cup center, and the arrow representing the reaming direction.

During swing phase, it was determined that unaccounted for acetabular cup shifting of 5–10 mm leads to capsular ligament laxity coupled with an increase in hip joint instability. Two swing phase scenarios were assessed, one simulating adequate capsular tension and therefore a uniform contact patch and the other simulating inadequate capsule tension and therefore femoral component pistoning with a smaller contact patch (Figure 2). During stance phase, it was determined that acetabular cup shifting of 5–10 mm in the medial and/or superior directions yields an increase in hip joint instability. Two stance phase scenarios were simulated, one yielding no hip separation and therefore a uniform, centralized contact patch, and the other yielding ∼1.5 mm of hip separation and therefore a non-uniform, supero-lateral edge loading patch (Figure 3).

Cup orientation does not appear to directly cause hip instability, but it will either lessen or exacerbate the instability, depending on the specific scenario. The results in this study did reveal that overly-inclined cups will yield less stability in the lateral direction, and overly-anteverted cups will yield less stability in the anterior direction.

Discussion

In general, instability during stance phase comes in the form of femoral head sliding and edge loading, and instability during swing phase comes in the form of femoral head pistoning. This study's analyses did reveal that proper alignment of the acetabular cup is required for ideal clinical results. The results from this study dictate that proper translational alignment of the cup as well as rotational alignment is necessary for patient stability and proper hip mechanics.