Full Access

General Orthopaedics

USE OF BIOMARKERS AND CELL COUNT ON SYNOVIAL FLUID IN THE DIAGNOSIS OF PROSTHETIC JOINT INFECTION

The European Bone and Joint Infection Society (EBJIS) 2018 Meeting, Helsinki, Finland, September 2018.



Abstract

Aim

We report on the performance of a simple algorithm using a combination of synovial fluid White blood cell count(WBC), C-reactive protein(CRP) and α-Defensin(AD) tests to aid in the diagnosis of prosthetic joint infections.

Methods

Sixty-six synovial fluid samples were collected prospectively in patients with suspected PJI (hip and knee). All samples were tested by: WBC counts (read manually) and CRP test (Alere-Afinion™ validated in-house); and on 37 of these with AD test.

Synovial fluid samples were collected in 5 ml ethylenediaminetetraacetic acid (EDTA) tubes. Samples that were very viscous were pre-processed by the addition of 100µl of hyaluronidase solution. Grossly blood stained and clotted samples were excluded.

A clinical diagnosis of infection was based IDSA definitions1. Cut offs of >3000 × 106 cells/L for total synovial WBC count and >12mg/L for CRP were used to define infection2,3.

Results

Of 66 samples tested, 20 samples were categorised as clinically infected. Combination of WBC count and CRP yielded a sensitivity of 95% (95% CI: 75.13% to 99.87%) and specificity of 100% (95% CI: 92.29% to 100.00%). Only one patient, who had a chronic infection with S.epidermidis and S.warneri, had a CRP and WBC count that was falsely negative (<5mg/L and 93 × 106 cells/L respectively). AD test was used on 37 samples (of which 20 were infected). Sensitivity of this test alone was 85.71% (95% CI: 63.66% to 96.95%) and specificity 87.5% (95% CI: 61.65% to 98.45%). There were 2 falsely positive AD test results (one of whom had a metal on metal prosthesis) and 3 false negative results (2 E.coli infections and one patient with chronic infection with S.epidermidis and S.warneri).

Conclusion

Use of a combination of synovial fluid WBC count and CRP (both of which can be performed using simple and inexpensive laboratory tests), has a sensitivity of 95% and 100% specificity in the diagnosis of PJI. AD test may be useful on some occasions when near patient testing result may affect patient management.


Email: