Abstract

Stems are a crucial part of implant stabilization in revision total knee arthroplasty. In most cases the metaphyseal bone is deficient, and stabilization in the diaphyseal cortical bone is necessary to keep the implant tightly fixed to bone and to prevent tilt and micromotion. While sleeves and cones can be effective in revision total joint arthroplasty, they are technically difficult and may lead to major bone loss in cases of loosening or infection, especially if the stem is cemented past the cone. A much more conservative method is to ream the diaphysis to the least depth possible to achieve tight circumferential fixation, and to apply porous augments to the undersurface of the tibial tray or inner surface of the femoral component to allow them to bottom out against the bone surface and apply compressive load. If a robust, strong taper, stem and component combination is used, rim contact on only one side is necessary to achieve rigid permanent fixation.

Porous and non-porous stems are available. The non-porous stems should have a spline surface that engages the diaphyseal bone and achieves rigid initial fixation but does not provide long-term axillary support. In that way the porous rim-engaging surface can bear compressive load and finally unload the stem and taper junction.

Correctly designed stems do not stress relieve unless they are porous-coated. In situations where metaphyseal bone is not available, porous-coated stems that link to hinge prostheses are a very important part of the armamentarium in complex revision arthroplasty.

Use of stems requires experience and special technique. Slight underreaming and initial scratch fit are necessary techniques. This does not result in tight fixation every time because split of the cortex does occasionally occur. In most cases these splits do not need to be repaired, but when there is a question, an intra-operative x ray should be taken and the surgeon should be prepared to repair the fracture.

Stems are an essential part of revision total knee arthroplasty. A tightly fit stem in the diaphysis is necessary for fixation when metaphyseal bone is deficient. No amount of cement pressed into the deficient metaphyseal bone will substitute for rigid stem fixation..