header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

KINEMATIC ALIGNMENT OPTIMIZES PATIENT OUTCOME – AFFIRMS

Current Concepts in Joint Replacement (CCJR) Winter 2017 Meeting, Orlando, FL, USA, December 2017.



Abstract

Conventional total knee arthroplasty aims to place the joint line perpendicular to the mechanical axis resulting in an overall neutral mechanical alignment. This objective is promulgated despite the fact healthy adult populations are on average in varus with few proximal tibias being neutral to the mechanical axis. The goal of a neutral mechanical axis is based largely on historical studies and the fact that it is easier to make a neutral tibial cut with conventional jigs and the eye. In order to balance the flexion and extension gaps to accommodate a neutral tibial cut, in most patients, asymmetrical distal and posterior femoral cuts are required. The resulting position of the femoral component could be considered to be “mal-rotated” with respect to the patient's soft tissue envelope. Soft tissue releases are often required to “balance” the knee. Planning and execution of the surgery are largely based off 2-dimensional radiographs which grossly oversimplifies the concept of alignment to the coronal plane, largely ignoring what happens to the knee in 3-dimensions through range of motion and 4-dimensions with respect to gait, stair climbing, etc. Subsequently, neutral mechanical for all engenders the “looks good, feels bad” phenomenon seen in many patients that may in part drive the higher dissatisfaction rates seen in knee arthroplasty globally compared to hip arthroplasty.

Additionally, because most tibias are in varus in the native state, placement of the tibial component in a neutral position results in a valgus orientated position during weight bearing post-operatively. Placing the tibial component in a varus, kinematic aligned position negates this deleterious condition and has been linked to improved outcomes in recent studies.

New imaging and surgical techniques allow for the identification of patient specific alignment targets and the ability to more precisely execute the surgical plan with respect to 3-dimensional placement of the components. Long-term outcomes studies as well as more recent studies on “kinematic” positioning suggest that deviation away from a neutral mechanical target is safe with respect to survivorship and provides better function with a more “natural” feeling knee.