header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

FEMORAL STEM IMPACTION GRAFTING: EXTENDING THE ROLE OF CEMENT

Current Concepts in Joint Replacement (CCJR) Winter 2017 Meeting, Orlando, FL, USA, December 2017.



Abstract

Femoral revision after cemented total hip arthroplasty (THA) might include technical difficulties, following essential cement removal, which might lead to further loss of bone and consequently inadequate fixation of the subsequent revision stem. Bone loss may occur because of implant loosening or polyethylene wear, and should be addressed at time of revision surgery. Stem revision can be performed with modular cementless reconstruction stems involving the diaphysis for fixation, or alternatively with restoration of the bone stock of the proximal femur with the use of allografts.

Impaction bone grafting (IBG) has been widely used in revision surgery for the acetabulum, and subsequently for the femur in Paprosky defects Type 1 or 2. In combination with a regular length cemented stem, impaction grafting allows for restoration of femoral bone stock through incorporation and remodeling of the proximal femur. Cavitary bone defects affecting the metaphysis and partly the diaphysis leading to a wide femoral canal are ideal indications for this technique. In case of combined segmental-cavitary defects a metal mesh is used to contain the defect which is then filled and impacted with bone grafts. Cancellous allograft bone chips of 2 to 4 mm size are used, and tapered into the canal with rods of increasing diameters. To impact the bone chips into the femoral canal a dummy of the dimensions of the definitive cemented stem is inserted and tapped into the femur to ensure that the chips are firmly impacted. Finally, a standard stem is implanted into the newly created medullary canal using bone cement. To date several studies from Europe have shown favorable results with this technique, with some excellent long-term results reported.

Advantages of IBG include the restoration of the bone stock in the proximal femur, the use of standard length cemented stems and preserving the diaphysis for re-revision. As disadvantages of the technique: longer surgical time, increased blood loss and the necessity of a bone bank can be mentioned.