Full Access

General Orthopaedics

TEN-YEAR SURVIVAL OF NAVIGATION-ASSISTED UNICOMPARTMENTAL KNEE ARTHROPLASTY

International Society of Computer-Assisted Orthopaedic Surgery (CAOS), 17th Annual Scientific Meeting, Aachen, June 2017



Abstract

INTRODUCTION

Unicompartmental knee arthroplasty (UKA) is considered a highly successful procedure. However, complications and revisions may still occur, and some may be related to the operative technique. Computer assistance has been suggested to improve the accuracy of implantation of a UKA. The present study was designed to evaluate the long-term (more than 10 years) results of an UKA which was routinely implanted with help of a non-image based navigation system.

MATERIAL AND METHODS

All patients operated on between 2004 and 2005 for implantation of a navigated UKA were included. Usual demographic and peri-operative items have been record. All patients were prospectively followed with clinical and radiological examination. All patients were contacted after the 10 year follow-up for repeat clinical and radiological examination (KSS, Oxford knee questionnaire and knee plain X-rays). Patients who did not return were interviewed by phone call. For patients lost of follow-up, family or general practitioner was contacted to obtain relevant information about prosthesis survival. Survival curve was plotted according to Kaplan-Meier.

RESULTS

57 UKAs were implanted during the study time-frame. Final follow-up (including death or revision) was obtained for 50 cases (88%). Clinical status after 10 years was obtained for 45 cases (80%). 4 prosthetic revisions were performed for mechanical reasons during the follow- up time (7%). The 10 year survival rate was 94%. No component was considered loose at the final radiographic evaluation. No polyethylene wear was detected at the final radiographic evaluation.

DISCUSSION

This study confirms our initial hypothesis, namely quite satisfactory results of a navigated implanted UKA after more than 10 years. Navigation, whose precision is no longer to be demonstrated, probably contributed to the quality of the results. A more consistent anatomical reconstruction and ligamentous balance of the knee should lead to more consistent survival of the UKA. However, superiority of navigated UKA in comparison to conventional implanted UKA is difficult to prove because of the subtle differences expected in mostly underpowered studies. Longer term follow-up may be required.