161 – TOTAL KNEE ARTHROPLASTY AFTER DISTAL FEMORAL VARUS OSTEOTOMY: MID-TERM RESULTS OF SELECTIVELY STEMMED POSTERIOR STABILISED COMPONENTS



Abstract

Purpose: The literature regarding the outcome of total knee arthroplasty following distal femoral varus osteotomy is limited. The largest published series to date of eleven such patients suggested that medio-lateral constrained implants are commonly required as ligament balancing is difficult. This study presents mid-term outcomes of patients treated with total knee arthroplasty following distal femoral varus osteotomy at a single center.

Method: Twenty-two consecutive distal femoral varus osteotomies (21 patients) converted to total knee arthroplasties were reviewed at a mean follow-up of five years (range, two to 14 years). The mean duration between osteotomy and conversion to arthroplasty was 12 years (range, three to 21 years). In 14 patients (15 knees) the underlying etiology for the femoral osteotomy was primary knee osteoarthritis with valgus deformity, while in seven patients the procedure was performed to unload a fresh osteochondral allograft of either the lateral tibia (five patients) or femur (two patients). It is the authors’ routine to use posterior stabilized implants were used in all total knee arthroplasty surgeries. Femoral stems were used in six knees in which the bone quality was clinically determined by the surgeon to be sufficiently deficient to predispose to periprosthetic fractures, while the remaining sixteen knees were treated with unstemmed components. Modified knee society scores were used to evaluate the clinical outcomes preoperatively and at most recent follow-up.

Results: The mean knee society knee and function scores in surviving knees improved from 50 points (range, 10 to 75 points) and 50 points (range, 30 to 70 points) pre-operatively, to 91 points (range, 67 to 100 points) and 64 points (range, 50 to 70 points) at final follow-up, respectively. The mean arc of motion improved from 94 degrees (range, 70 to 115 degrees) to 114 degrees (range, 90 to 130 degrees). Two patients underwent revision arthroplasty for polyethylene wear and component loosening at eight and 11 years following the index arthroplasty, respectively. There were no fractures, infections or wound complications.

Conclusion: Total knee arthroplasty following distal femoral varus osteotomy reliably decreases pain and improves knee function. Standard posterior stabilized components provide satisfactory stability after appropriate ligamentous balancing, without the need for stemmed or highly constrained components in the majority of patients.

Correspondence should be addressed to: COA, 4150 Ste. Catherine St. West Suite 360, Westmount, QC H3Z 2Y5, Canada. Email: meetings@canorth.org